Ethernet Cable Types

Cat5, Cat6, Cat6a specifications, fiber optic cables, and physical layer requirements.

The Foundation: The Physical Medium

A computer network is fundamentally about moving information from one point to another. While we often think about the complex software and protocols involved, none of it would be possible without the physical foundation: the transmission medium. This medium is the physical channel through which the signals (whether electrical pulses, flashes of light, or radio waves) travel.

Choosing the right medium is one of the most critical decisions in network design. The choice depends on several key criteria:

  • Distance: How far does the signal need to travel without significant degradation?
  • Environment: In what physical conditions will the medium be installed? Is it a quiet office, a factory floor with heavy machinery, or outdoors?
  • Bandwidth and Speed: How much data needs to be transmitted per second?
  • Cost: What is the budget for the material and its installation?

For wired Ethernet, the history of networking is primarily the story of two types of physical media: copper cables and, more recently, fiber optic cables.

Copper Cabling: The Ubiquitous Workhorse

For decades, copper wiring has been the backbone of local area networking. It transmits data using electrical impulses, with different voltage levels representing the ones and zeros of binary data. There are two main types of copper cables that have been central to Ethernet's history and current use.

1. Coaxial Cable

Coaxial cable, or "coax," consists of a central copper conductor surrounded by a layer of insulation (the dielectric), which is then covered by a metallic shield (a braid or foil), and finally a protective outer jacket. This structure creates a contained electromagnetic field, providing good shielding against outside interference.

  • Historical Role: Coax was the original medium for Ethernet in the 10Base-5 ("Thicknet") and 10Base-2 ("Thinnet") standards.
  • Modern Use: While obsolete for modern LANs, it remains the standard for cable television (CATV), satellite installations, and cable modems, thanks to its high bandwidth and excellent shielding.
  • Impedance: Coaxial cables are defined by their characteristic . The two common standards are 75 Ω (used for video applications) and 50 Ω (used for data and RF communications).

2. Twisted-Pair Cable

Twisted-pair is the most popular type of cabling used in modern Ethernet LANs. A single cable contains four pairs of insulated copper wires that are twisted around each other.

Why Twist the Wires? The Magic of Cancellation

The twist is the single most important feature of this cable type. It ingeniously protects the signal from two major problems:

  • Noise from External Sources (EMI): When an external electromagnetic field (e.g., from fluorescent lights or motors) passes through the cable, it induces a small, unwanted current (noise) in the wires. Because the wires are twisted, each wire is equally exposed to the interference, but in opposing orientations in each twist. This causes the induced noise signals on the two wires to be nearly identical but of opposite phase, effectively canceling each other out when the signal is processed by a differential receiver.
  • Crosstalk from Adjacent Pairs: The electrical signal flowing through one pair creates its own small magnetic field, which can induce a signal in an adjacent pair. This is called crosstalk. By twisting the pairs (each with a different twist rate), the magnetic fields they generate are also constantly changing orientation, which cancels out most of the potential interference between pairs within the same cable.

Types of Twisted-Pair: Shielding and Nomenclature

Twisted-pair cables are categorized based on whether they include additional metallic shielding to further protect against interference. The standard nomenclature is XX/YTP, where XX describes the outer shield for the whole cable, and Y describes the shielding for individual pairs.

  • U/UTP (Unshielded Twisted Pair):Commonly just called UTP. This is the simplest and most common type of Ethernet cable. It has no overall shield (first 'U') and no individual shields on the pairs (second 'U'). It relies solely on the twisting of the pairs for noise rejection. It is perfectly suitable for most office and home environments.
  • F/UTP (Foiled with Unshielded Twisted Pair):Often called FTP. This cable has an overall aluminum foil shield ('F') wrapped around all four unshielded pairs ('UTP'). This provides a good degree of protection from external EMI and is a popular choice for installations with moderate electrical noise.
  • S/FTP (Shielded with Foiled Twisted Pair):This cable offers a very high level of protection. Each individual pair is wrapped in its own foil shield ('FTP'), which minimizes crosstalk between them. Additionally, there is an overall braided shield ('S') around the entire cable for excellent protection against external noise. This type is used in high-speed applications like 10 Gigabit Ethernet or in very noisy industrial environments.
  • SF/UTP (Shielded and Foiled with Unshielded Twisted Pair):This cable features a dual outer shield consisting of both a braid ('S') and a foil ('F') for maximum EMI protection, while the internal pairs remain unshielded ('UTP').

Properly grounding the shield is critical for shielded cables to be effective. An ungrounded shield can act like an antenna, potentially making the interference problem worse.

Twisted-Pair Performance: Categories

Besides shielding, twisted-pair cables are classified into categories (defined by TIA) or classes (defined by ISO/IEC) based on their electrical performance, primarily their . A higher category number signifies a cable that can reliably transmit data at higher frequencies, which in turn enables higher speeds.

CategoryBandwidthCommon Application(s)
Category 316 MHzLegacy telephone systems, 10Base-T Ethernet (10 Mbps). Now obsolete for data networks.
Category 5e100 MHzThe longtime workhorse. Minimum standard for 100Base-TX (100 Mbps) and 1000Base-T (1 Gbps) networks.
Category 6250 MHzProvides better performance and less crosstalk than Cat 5e. Supports 1 Gbps reliably and 10GBase-T up to 55 meters.
Category 6A500 MHzThe "A" stands for Augmented. Specifically designed to support 10GBase-T (10 Gbps) over the full 100-meter distance.
Category 7/7A600 / 1000 MHzFully shielded cabling (S/FTP) with even stricter specifications. Supports 10 Gbps and future higher speeds but requires non-RJ45 connectors for full performance.

The Future: Fiber Optic Cabling

Fiber optic cable represents a monumental leap in transmission technology. Instead of electrical impulses, it uses pulses of light traveling down a hair-thin strand of high-purity glass (the core) to transmit information. The light is kept inside the core by a principle called , bouncing off the boundary with another layer of glass called the cladding.

Key Advantages of Fiber Optics

  • Immense Bandwidth: A single fiber can carry thousands of times more data than a copper cable. Modern systems transmit terabits per second over a single strand.
  • Long Distances: Light signals suffer much lower than electrical signals, allowing them to travel many kilometers without needing amplification.
  • Immunity to EMI: Since the signal is light, it is completely immune to electrical noise, crosstalk, and lightning, making it ideal for electrically noisy environments like factory floors or for running alongside power lines.
  • Security: It is extremely difficult to "tap" a fiber optic cable without being detected, making it more secure than copper.

Types of Fiber Optic Cable

Multimode Fiber (MMF)

MMF has a relatively large core diameter, allowing multiple paths or "modes" of light to travel down the fiber simultaneously. This makes it easier to work with but causes a phenomenon called modal dispersion, where different modes arrive at the receiver at slightly different times, blurring the signal. It is used for shorter distances (up to ~2 km) in LAN backbones and data centers.

Single-mode Fiber (SMF)

SMF has an extremely small core diameter, so narrow that it forces light to travel in only a single path or mode. This eliminates modal dispersion, allowing the signal to travel very long distances (hundreds of kilometers) at extremely high speeds. It is the standard for all long-haul, metropolitan, and carrier networks.

Fiber Optic Transmission Windows

Fiber optic glass is not equally transparent to all wavelengths (colors) of light. There are specific ranges of wavelengths where attenuation is lowest, known as "transmission windows".

Optical fiber attenuation windows

Tap a window to see why different wavelengths matter in Ethernet optics.

≈ λ 1270–1330 nm
Optical fiber attenuation windowsTap a window to see why different wavelengths matter in Ethernet optics.1st window820–920 nm2nd window1270–1330 nm3rd window1530–1570 nm4th window1600–1650 nm01234585010001310155016501800Attenuation (dB/km)Wavelength λ (µm)Rayleigh scatteringOH- water peakInfrared absorption
Second window (1310 nm)
λ ≈ 1310 nm

Dispersion minimum for standard single-mode fiber. Balanced cost and performance.

Typical applications

  • 1000BASE-LX, 10GBASE-LR without dispersion compensation
  • Metro and access rings up to ~10 km

Typical attenuation: ~0.35 dB/km

  • First Window (850 nm): Used primarily with multimode fiber for short-range applications like LANs.
  • Second Window (1310 nm): Offers lower attenuation than the first window and has the unique property of having near-zero chromatic dispersion in standard single-mode fiber, making it ideal for high-speed transmission.
  • Third Window (1550 nm): This window boasts the lowest attenuation of all, making it the primary choice for long-haul and undersea communication systems. This is the window where Wavelength Division Multiplexing (WDM) technologies thrive.
  • Fourth Window & L-Band (1565-1625 nm and beyond): These represent extensions to the third window, allowing carriers to pack even more channels onto a single fiber to meet ever-growing bandwidth demands.